JSP CAU660-000-400 Replacement Powercap Infinity Filters - Pack of 2
(650997)£29.99
EX VAT
(£35.99 INC VAT)
JSP CAU660-000-400 Replacement Powercap Infinity Filters - Pack of 2
Key Features
- TH3P R SL particulate filtration provides the highest level of respiratory protection available under EN12941:1998 + A2:2008 standards.
- High efficiency filter media captures dust, spores, mist and fumes for reliable particulate protection in demanding environments.
- Designed specifically for the JSP Powercap Infinity powered air purifying respirator to ensure correct fit and airflow balance.
- Supplied as a matched pack of two filters which must always be replaced simultaneously to maintain system performance.
- Delivers a nominal protection factor of 500, equivalent to UK APF40, for enhanced safety during prolonged use.
£29.99
EX VAT
-
Free Gift
-
Promotion:
-
Promotion:
-
Promotion:
-
Promotion:
-
Promotion:
-
Promotion:
Added for collection
JSP CAU660-000-400 Replacement Powercap Infinity Filters - Pack of 2
Description
-
Product Code:JSPCAU660000400
-
Model Number: CAU660-000-400
-
Brand: JSP
-
Barcode: 5038428227384
-
Category: Face Mask Accessories
-
Taxonomy: Business & Industrial > Work Safety Protective Equipment > Protective Masks > Gas Masks & Respirators
The JSP CAU660-000-400 Replacement Powercap Infinity Filters from ITS are genuine TH3P R SL particulate filters designed to maintain the highest level of respiratory protection when used with the JSP Powercap Infinity powered air purifying respirator.
These replacement filters are supplied as a pack of two and must always be replaced together to ensure balanced airflow and consistent protection performance.
Each filter is manufactured to meet EN12941:1998 + A2:2008 standards and delivers TH3 protection with a nominal protection factor of 500, equivalent to UK APF40, making them suitable for demanding industrial and construction environments.
The high efficiency particulate filter media is engineered to capture most particulate matter including dust, spores, mist and fumes, helping to protect tradesmen working in high exposure conditions.
These filters are not designed to filter gases, vapours or toxic substances and should only be used for particulate protection applications as specified by JSP.
Regular inspection and timely replacement are essential, as filter lifespan varies depending on working conditions, airborne contamination levels and usage duration.
Only genuine JSP Powercap Infinity filters should be used to maintain certification compliance and system integrity, and compressed air should never be used for cleaning as this can severely reduce filtration performance and protection.
Specification
| Buying Option | Pack of 2 |
| Pack Size | 2 |
| Product Weight | 0.16kg |
| Protection Level | TH3 |
| Standards/Approvals | EN 12941:1998 |
| Standards/Approvals | A2:2008 |
| Respirator Style | Filter |
Product is also in :
Customer Reviews
Ask a Question
Questions Answered
Key Features
- TH3P R SL particulate filtration provides the highest level of respiratory protection available under EN12941:1998 + A2:2008 standards.
- High efficiency filter media captures dust, spores, mist and fumes for reliable particulate protection in demanding environments.
- Designed specifically for the JSP Powercap Infinity powered air purifying respirator to ensure correct fit and airflow balance.
- Supplied as a matched pack of two filters which must always be replaced simultaneously to maintain system performance.
- Delivers a nominal protection factor of 500, equivalent to UK APF40, for enhanced safety during prolonged use.
Description
Description
-
Product Code:JSPCAU660000400
-
Model Number: CAU660-000-400
-
Brand: JSP
-
Barcode: 5038428227384
-
Category: Face Mask Accessories
-
Taxonomy: Business & Industrial > Work Safety Protective Equipment > Protective Masks > Gas Masks & Respirators
The JSP CAU660-000-400 Replacement Powercap Infinity Filters from ITS are genuine TH3P R SL particulate filters designed to maintain the highest level of respiratory protection when used with the JSP Powercap Infinity powered air purifying respirator.
These replacement filters are supplied as a pack of two and must always be replaced together to ensure balanced airflow and consistent protection performance.
Each filter is manufactured to meet EN12941:1998 + A2:2008 standards and delivers TH3 protection with a nominal protection factor of 500, equivalent to UK APF40, making them suitable for demanding industrial and construction environments.
The high efficiency particulate filter media is engineered to capture most particulate matter including dust, spores, mist and fumes, helping to protect tradesmen working in high exposure conditions.
These filters are not designed to filter gases, vapours or toxic substances and should only be used for particulate protection applications as specified by JSP.
Regular inspection and timely replacement are essential, as filter lifespan varies depending on working conditions, airborne contamination levels and usage duration.
Only genuine JSP Powercap Infinity filters should be used to maintain certification compliance and system integrity, and compressed air should never be used for cleaning as this can severely reduce filtration performance and protection.
Specification
- Buying Option Pack of 2
- Pack Size 2
- Product Weight 0.16kg
- Protection Level TH3
- Standards/Approvals EN 12941:1998
- Standards/Approvals A2:2008
- Respirator Style Filter